| Topology | Double-conversion, online | |
| Configuration | Rack/tower | |
| Color | Black and silver | |
| Diagnostics | Full system self-test at power up, ABM test every 30 days | |
| Warranty | 2 years electronics and battery | |
| | |
| Rail kit | 4-post rail kit included;
Max length:30.0in, Min length:17.4in
Tower pedestals included
Optional 2-post rail kit available, part number: 103007018-5591 | |
| Remote power off | Remote On/Off (ROO) and Remote Power Off (RPO) rear terminal blocks | |
| Contents (Ships with the following items) | UPS
4-post rail kit
Safety manual
User manual
Output cables (for G models)
Input cables (for G models)
Cable lockers (for G models)
Tower pedestals
RS-232 serial cable
USB cable
Communication Card (Optional) | |
| | |
Electrical input | 208V | 120V |
| Nominal voltage | 208V default (200/208/220/230/240V) | 120V default (100/110/120/125V) |
| Input voltage range | Full load: 176-276V,
<40% load: 100-276V | Full load: 100-144V,
<30% load: 60-144V |
| Frequency | 50/60 Hz | 50/60 Hz |
| Frequency range | 60 Hz: 50–70 Hz, 50 Hz: 40–60 Hz | 60 Hz: 50–70 Hz, 50 Hz: 40–60 Hz |
| Input power factor | > .99 | > .99 |
| Input current distortion | < 5% ( < 10% frequency converter mode) | < 5% ( < 10% frequency converter mode) |
| Circuit breaker | 2200VA: None
3000VA: None | 2000VA: None
3000VA: (3) 20A for (2) 5-20R each |
Electrical output | 208V | 120V |
| Power ratings | | 9PX700RT: 700VA / 630W |
| 9PX1000GRT: 1000VA / 900W | 9PX1000RT: 1000VA / 900W |
| 9PX1500GRT & 9PX1500GRT-L
220/230/240V: 1500VA / 1500W
200/208V: 1350 | 9PX1500RT & 9PX1500RT-L
120/125V: 1500VA / 1350W
110V: 1350VA / 1215W
100V: 1200VA / 1080W |
| 9PX2200GRT & 9PX2200GRT-L:
220/230/240V: 2200VA / 2200W
208/200V: 2200VA / 2000W | 9PX2000RT& 9PX2000RT-L:
120/125V: 2000VA / 1800W
110V: 1800VA / 1620W
100V: 1600VA / 1440W |
| 9PX3000GRT & 9PX3000GRT-L & 9PX3000GLRT & 9PX3K3U models:
220/230/240V: 3000VA / 3000W
208/200V: 3000VA / 2700W | 9PX3000RT & 9PX3000RT-L:
120/125V: 3000VA / 2700W
110V: 2700VA / 2430W
100V: 2400VA / 2160W |
| Nominal voltage | 208V default (200/208/220/230/240V) | 120V default (100/110/120/125V) |
| Output voltage regulation, steady state | ±1% normal mode
±2% battery mode | ±1% normal mode
±2% battery mode |
| Voltage THD (online) | Linear: 3%
Non-linear: 5% | Linear: 3%
Non-linear: 5% |
| Power factor | 0.9 | 0.9 |
| Efficiency | 9PX1000GRT: 90% online
9PX1500GRT: 91% online
9PX1500GRT-L: 92% online
9PX2200GRT: 93% online
9PX2200GRT-L: 93% online
9PX3000GRT: 93% online
9PX3000GRT-L: 93.7% online
9PX3000GLRT: 93% online
9PX3K3U Models: 93% online | 9PX700RT: 89.9% online
9PX1000RT: 90% online
9PX1500RT: 90% online
9PX1500RT-L: 90% online
9PX2000RT: 91% online
9PX2000RT-L: 91.4% online
9PX3000RT: 91% online
9PX3000RT-L: 91.6% online |
| Transfer time | 0 ms | 0 ms |
| | |
Battery | | |
| Optional extended battery module (EBM) | Lead Acid
9PXEBM36RT: 700/1000 VA models
9PXEBM48RT: 1500 VA models
9PXEBM72RT: 2000-3000 models
9PXEBM180RT: 9PX3K3U Models
Lithium ion
9PXEBM48RT-L: 1500 VA models
9PXEBM72RT-L: 2000-3000 models | Lead Acid
9PXEBM36RT: 700/1000 VA models
9PXEBM48RT: 1500 VA models
9PXEBM72RT: 2000-3000 models
Lithium ion
9PXEBM48RT-L: 1500 VA models
9PXEBM72RT-L: 2000-3000 models |
| Maximum number of EBMs | Add up to 4 EBMs | Add up to 4 EBMs |
| Battery description | Sealed, lead-acid; maintenance free
or
Lithium Ion (LFP Chemistry) | Sealed, lead-acid; maintenance free
or
Lithium Ion (LFP Chemistry) |
| Battery management | ABM technology; 3-stage charging extends battery service life up to 50% and provides advance warning for battery replacement | ABM technology; 3-stage charging extends battery service life up to 50% and provides advance warning for battery replacement |
| Battery replacement | Hot-swappable internal batteries and EBMs | Hot-swappable internal batteries and EBMs |
| Start on battery | Cold-start enabled; first cold start is always forbidden | Cold-start enabled; first cold start is always forbidden |
| | |
Communications | | |
| User interface | Graphical display. UPS status in a single view. | Graphical display. UPS status in a single view. |
| LEDs | 4 status-indicating LEDs | 4 status-indicating LEDs |
| Communication ports | RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included | RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included |
| Communications card | Network Card-MS optional, standard on network bundles (bundled models include an N) | Network Card-MS optional, standard on network bundles (bundled models include an N) |
| Power management software | Integrates with Eaton Intelligent Power Manager software | Integrates with Eaton Intelligent Power Manager software |
| | |
Environmental & standards | | |
| RoHS compliance | Yes | Yes |
| Surge protection | MOV: 510V, 296Joules | MOV ratings : 271Volt (from L-N) and 510 Volt (from L-G and N-G), 190 Joules |
| EMC markings | IEC 62040-2 Class B Cat C2 / CISPR22
Class B / FCC part 15 Class B / VCCI Class B | IEC 62040-2 Cat C1 / CISPR22 / FCC part
15 Class B / VCCI Class B |
| Heat dissipation (BTU) | 9PX1000GRT: 267 online, 438 battery
9PX1500GRT: 494 online, 731 battery
9PX2200GRT: 513 online, 741 battery
9PX3000GRT: 619 online, 1150 battery
9PX3000GLRT: 619 online, 1150 battery | 9PX700RT: 241 online, 440 battery
9PX1000RT: 330 online, 646 battery
9PX1500RT: 512 online, 897 battery
9PX2000RT: 578 online, 974 battery
9PX3000RT: 844 online, 1462 battery |
| Audible noise | < 47 dB at 1 meter | < 47 dB at 1 meter |
| Operating temperature | 0 to 40°C (32°F to 104°F) | 0 to 40°C (32°F to 104°F) |
| Altitude operating temperature range | 0-1500m @ 0°C - 40°C
1500m-3000m @ 0°C - 35°C | 0-1500m @ 0°C - 40°C
1500m-3000m @ 0°C - 35°C |
| Safety conformance | CE / cULus | CE / cULus / NOM |
| Storage temperature | 0 to 35°C (32°F to 95°F); without batteries: -15 to 55°C (5°F to 131°F) | 0 to 35°C (32°F to 95°F); without batteries: -15 to 55°C (5°F to 131°F) |
| Relative humidity | 0 to 96% non-condensing | 0 to 96% non-condensing |