 [Formerly EATON 9E] An all-in-one solution that reduces installation & startup complexity, as well as providing maximum runtime, the EATON 93E UPS is engineered to deliver the most efficient power quality solution across the three areas that count most: space, power, and cost. With its internal batteries providing up to 60 KVA, EATON 93E Uninterruptible Power Supply Systems (UPS) delivers up to 98 percent efficiency while maintaining a small physical footprint.
[Formerly EATON 9E] An all-in-one solution that reduces installation & startup complexity, as well as providing maximum runtime, the EATON 93E UPS is engineered to deliver the most efficient power quality solution across the three areas that count most: space, power, and cost. With its internal batteries providing up to 60 KVA, EATON 93E Uninterruptible Power Supply Systems (UPS) delivers up to 98 percent efficiency while maintaining a small physical footprint.Features & Benefits Of 93E UPS (Uninterruptible Power Supply Systems)
- Upgradeable UPS System with modular design
- Single cabinet design reduces installation, wiring, and maintenance costs
- Up to 35 percent smaller footprint than similar industrial UPS systems or commercial UPS systems
- 98 percent efficiency for lower operating cost
- Runtime up to 21 minutes using internal batteries
- Runtime up to 138 minutes when paired with an Extended Battery Cabinet (EBC)
- Intelligent Power Manager software monitors & manages multiple power devices across your network
- Detachable maintenance bypass options for zero downtime
- One year parts & labor warranty included with Eaton startup protection plan to the load
Product Snapshot
| PRODUCT SNAPSHOT | |
|---|---|
| Power Rating | 20-60 kVA | 
| Voltage | 208/220 Vac three phase | 
| Frequency | 50/60 Hz | 
| Configuration | Tower | 
| GENERAL | |
|---|---|
| Topology | Double-conversion online | 
| Configuration | Tower | 
| Rating (VA/Watts) | 20 kVA/16 kW | 
| Efficiency | Up to 98% High-efficiency mode, Up to 92% Double-conversion | 
| UPS Bypass | Automatic on overload or UPS failure | 
| Dimensions (H x W x D, inches) | 53.5 x 20.9 x 31.5 | 
| Dimensions (H x W x D, mm) | 1360 x 530 x 800 | 
| ELECTRICAL INPUT | |
| Connection | Hardwired | 
| Operating frequency | 50/60 Hz (45 to 65 Hz) | 
| Input power factor | 0.99 typical | 
| Input current distortion | <5% THD | 
| ELECTRICAL OUTPUT | |
| Nominal voltage | 208/220, 3/4 wire | 
| Output voltage regulation | ±1% Static; ±5% dynamic at 100% resistive load change, <20 ms response time | 
| Output Receptacles | Hardwired – see manual for terminal block layout | 
| Overload Capacity | 150% for 40 ms / 125% for 30 seconds / 110% for 10 min | 
| BATTERY | |
| Battery type | 9 Ah, sealed, lead-acid, maintenance-free | 
| Battery Management | ABM (Cyclic) or float | 
| Battery replacement | Field-replaceable | 
| Internal Batteries | Yes, has internal batteries. Field service upgrades needed to add external batteries (EBCs) to extend runtime | 
| COMMUNICATIONS | |
| User Interface | Graphical LCD with blue backlight | 
| LEDs | (4) LEDs for notice and alarm | 
| Audible alarms | Yes | 
| Communication ports | (1) RS-232, (1) REPO | 
| Communication slot | (2) Mini-slot communication bays | 
| Power management software | Eaton Intelligent Power Software Suite CD | 
| ENVIROMENTAL & STANDARDS | |
| Audible Noise | < 64 dBA at 1 meter (noise less room) typical | 
| Operating Temperature | 0ºC (32ºF) to +30ºC (86ºF); Batteries recommended max. +25ºC (77ºF) | 
| Safety markings | UL60950 , EN55022/EN55024 | 
| EMC Markings | IEC 62040-2 | 
| Markings | UL, cUL | 
| Storage Temperature | -25ºC (-13ºF) to +55ºC (131ºF) without batteries; +15ºC (59ºF) to +25ºC (77ºF) with batteries | 
| Relative Humidity | 5 –95%, non-condensing | 
| Altitude | < 1000m at +30°C (86ºF) | 
1. Due to continuous product improvements, program specifications are subject to change without notice.
Industries & Applications
The EATON 93E is designed to be one of the most versatile emergency power supply systems for enterprises in need of an industrial UPS system or a commercial UPS system. It delivers maximum power in the least amount of space for small-to-medium users who have unusually high power density requirements, including but not limited to:
- Data centers, IT systems, or telecom closets with relatively larger power needs
- Network switching & processing equipment
- PLC controls
- High-quality power backup system for AS-400 systems
- Hospitals, clinics, and medical centers
- Financial Institutions
[/et_pb_text][et_pb_text admin_label=”Other Uninterruptible Power Supply Models” background_layout=”light” text_orientation=”left” use_border_color=”off” border_color=”#ffffff” border_style=”solid”]
Other Uninterruptible Power Supply Models
| Part Number | Power Rating (VA/Watts) | Input Plug | Output Receptacles | 
|---|---|---|---|
| 93E (20 & 40 KVA) Models with Standard Runtime | |||
| 9EF02GG03001003 | 20000 / 16000 | Hardwired | Hardwired | 
| 9EG04GG03001003 | 40000 / 32000 | Hardwired | Hardwired | 
| 93E (20-30 KVA) Models for Extended Runtime | |||
| 9EA02GG05001003 | 20000 / 16000 | Hardwired | Hardwired | 
| 9EA03GG05001003 | 30000 / 24000 | Hardwired | Hardwired | 
| 93E (40-60 KVA) Models for External Runtime | |||
| 9EB04GG05001003 | 40000 / 32000 | Hardwired | Hardwired | 
| 9EB06GG05001003 | 60000 / 48000 | Hardwired | Hardwired | 